RELATIVE HUMIDITY - Temperature - Carbon Dioxide Datalogging KIT

RELATIVE HUMIDITY - Temperature - Carbon Dioxide Datalogging Kit

Our Item Number: M500
Manufacturer: TELAIRE
Manufacturer Number: 7001
Product Type: Indoor Air quality

Add to Cart

Record and log relative humidity, temperature & CO2 data…and graph right on your PC!

Features & Applications:

Poor Air quality cannot only affect ambient Air, but result in decay or damage to a structure. Equipped with infrared technology to accurately measure these components. Measure RH, temperature and CO2 with precision-enabling you to assess The conditions in The test area.

Designed for residential and commercial applications, it also has The ability to calculate and display cfm/person ventilation rate-hence identifying ventilation-related problems such as moisture build-up, combustion gas build-up, etc. Record your findings on your computer utilizing The included graphical software and cable.

Features:

  • Dual beam absorption infrared
  • Display: LCD
  • Sample method: diffusion or flow through (50 – 100 ml/min)
  • Power supply: 4 AA batteries (not included) or 6V DC from external AC/DC adapter (included)
  • Includes graphing software & computer cable

Applications:

  • Commercial
  • Residential

Spec Summary:

  • Temperature (internal sensor)

    • Range
      -4 to +158°F (-20 to +70°C)
      Range for internal sensor when used outside of case:
      -40 to +248°F (-40 to +120°C)

    • Accuracy
      ±1.27°F (±0.7°C) at +70°F

    • Resolution
      0.7°F (0.4°C) at +70°F

    • Response time still in Air
      15 min. typical with sensor inside case;
      1 min. typical with sensor outside case

  • Relative humidity (user-replaceable RH sensor)

    • Range
      25 to 95% RH at +80°F for intervals of > 10 seconds,
      non-condensing and non-fogging

    • Accuracy
      ±5%

    • Response time
      10 min. typical in Air

    • Sensor operating environment
      +41 to +122°F (+5 to +50°C)
      non-condensing and non-fogging

  • Power:

    • External input accepts The following sensors:
      Wide range of temp sensors (TMCx-Hx series)
      Split-core CTs for AC current (5 Models)
      4-20 mA input cable (CABLE-4-20mA)
      0-2.5 V DC input cable (Cable-2.5-Stereo)

      • Input range
        0 to +2.5 Volts DC

      • Resolution
        10 mV (8-bit)

    • External 2.5 Volt input
      2.5 mm jack: external input ground, input, switched 2.5 Volt output; external input ground connection is not The same as PC interface connection ground and should not be connected to any external ground

      • Accuracy
        ±10 mV ±1% of reading

      • Out power
        +2.5 Volts DC at 2 mA, active only during measurements

Bacharach - Gas Detectors
Bacharach
TIF Gas Detectors
TIF
UEI Gas Detectors
UEI
General Tools
General Tools
TPI
TPI