UEi C75 Combustion Gas Analyzer
Item #: G7100
Manufacturer: UEI
Manufacturer Item #: C75
Product Type: Combustion Gas Detector

|
|
UEi C75 Combustion Gas Analyzer Combustion tests residential combustion appliances and heating equipment
Features & Applications:
For professionals who value quality, functionability and precision-the UEi C75 Combustion Gas Analyzer fits the bill. Accurately and easily test residential combustion appliances and heating equipment with confidence. Check oxygen, ambient flue temps, calculated gross or net efficiency, CO2, excess air, CO and CO air free. This instrument's smart design allows hands free operation, as it comes with a magnetic protective boot that allows placement of meter on the side of an appliance or furnace. Then simply insert the flue probe and rotate the selector to make adjustments.
Features:
- Electronic Combustion Analyzer
- Measures O2, CO, stack and ambient temperature
- Calculates CO2, efficiency and CO air-free
- Large Back-lit, 2-line display
- Choose display parameter with DMM style selector
- Includes protective boot with integral magnet
- Infrared printer port - prints to optional printer
- Print-out includes date and time
Applications:
- Residential combustion appliances
- Residential heating equipment
- Check oxygen, ambient flue temps,
calculated gross or net efficiency,
CO2, excess air, CO and CO air
free
Spec Summary:
Parameter |
Resolution |
Accuracy |
Range |
Temperature: |
|
|
|
Flue temperature |
1°F/°C |
±5°F (2°C)
±0.3% reading
|
32-1,112°F
(0-600°C)
|
Gas Measurement: |
|
|
|
Oxygen |
0.1% |
±0.2% |
0-21% |
Carbon Monoxide
|
1ppm
|
±10ppm<100ppm
±5% of reading
|
0-2000ppm
4000ppm max
for 15 mins.
|
Carbon Dioxide
|
0.1%
|
±0.3% reading
|
0-30%
|
Efficiency
|
0.1%
|
±1.0 reading
|
0-99.9%
|
Excess Air
|
0.1%
|
±0.2%
|
0-250%
|
Dimensions:
|
|
|
|
Weight
|
2.2lb
|
Handset
|
8 x 2 x 3.5"
|
Probe
|
L 12 x Dia 0.25"
with 8" long
stainless steel shaft, type K
thermocouple and 9ft
long neoprene hose
|
Ambient Operating
Range:
|
32-104°F (0 to 40°C)
10 to 90% RH non-condensing
|
Battery Life:
|
Standard AA (x4)
>8 hours continuous use
|
AC adapter (optional):
|
Input: 110VAC/220 Vac nominal
Output: 6V DC 500mA
|
|